Medical Open Frame Power Supply UES150-XXXYYYSPA-OP

Medical Oen Frame Power Supply UES150-XXXYYYSPA-OP

PCB Board 24V 48V AC/DC Converter Switching Open Frame Power Supply

150 W

90~ 264 Vac input 

-30°C to +70°C temperature range

No-load power consumption < 0.21W

2 MOPP input to output isolation

Adjustable resistance to adjust output voltage

Convection cool

Application place: blood glucose analyzer, medical electric suction pump, portable ultrasonic detector, medium-sized electric infusion pump, large infrared physiotherapy device, skin treatment equipment

switching dc power supply

DESCRIPTION

The UES150-XXXYYYSPA-OP is a 150W open frame power supply, as well as an AC to DC PCB board switching converter power supply designed for home healthcare applications, housed in a compact board mount package. It offers multiple output options, including 12V, 15V, 18V, 24V, 36V, and 48V (coming with a universal input of 90 ~ 264 Vac), to cater to various medical devices. The series is designed for use in various medical products and is certified to the IEC 60601-1 3rd edition standard for 2 x MOPP applications. Featuring a no-load power draw of less than 0.21W and an efficiency of up to 94%, it suits medical devices, blood glucose analyzer, medical electric suction pump, portable ultrasonic detector, medium-sized electric infusion pump, large infrared physiotherapy device, skin treatment equipment.

SAFETY & COMPLIANCE

Safety Standards – IEC60601

Safety Approvals – CB

Model NumberPower(W)Input Voltage Range(VDC)Output Voltage(VDC)Output Current(A)Operating Temperature Range(℃)Efficiency Standards
UES150-XXXYYYSPA-OP132.090-26412.00.01-11.0-30~+70CE, UL/cUL,TUV
UES150-XXXYYYSPA-OP135.090-26415.00.01-9.00-30~+70CE, UL/cUL,TUV
UES150-XXXYYYSPA-OP144.090-26418.00.01-8.00-30~+70CE, UL/cUL,TUV
UES150-XXXYYYSPA-OP144.090-26424.00.01-6.00-30~+70CE, UL/cUL,TUV
UES150-XXXYYYSPA-OP144.090-26436.00.01-4.00-30~+70CE, UL/cUL,TUV
UES150-XXXYYYSPA-OP150.090-26448.00.01-3.12-30~+70CE, UL/cUL,TUV

RELATED APPLICATIONS

POPULAR QUESTIONS

Devices like ventilators, infusion pumps, surgical lighting, medical carts, and diagnostic lab equipment.

Different medical devices have varying power requirements—for example, 12V for control boards, 24V for pumps, and 48V for motor-driven systems.

It’s ideal for powering displays, fans, small suction units, and monitoring equipment.

It is widely used in CPAP machines, patient beds, therapy equipment, and lab analyzers.

Devices with higher loads, such as mobile workstations, powered medical trolleys, and surgical tools.

It should comply with IEC 60601-1 safety and IEC 60601-1-2 EMC standards, with 2x MOPP insulation.

Yes, if it meets the required medical-grade isolation, low leakage current, and safety standards.

Open frame designs typically rely on system-level airflow or heatsinks for effective heat dissipation.

Yes, especially the 18V–48V models are often used in RF, LED, and laser-based treatment systems.

Standard protections include OVP (Over Voltage), OCP (Over Current), SCP (Short Circuit), and OTP (Over Temperature).

FEATURED PRODUCTS

Power Solution for Sleep Monitors

One stop power supply solution Power Solution for Sleep Monitors Low-noise, stable, and safety-certified adapters for overnight sleep tracking and analysis Quankang offers professional-grade AC-DC

Read More »

FEATURED RESOURCES

CONTACT TECHNICAL SUPPORT

For additional assistance, please complete the form below, and an associate will be in touch with your shortly.

Request a Free Quote

Send us a message if you have any questions or request a quote. We will be back to you ASAP!