Medical Power Supply UES100B-SPCZ
Home Medical Power Supply UES100B-SPCZ/UES100C-SPCZ Desktop homecare 15v 20v switching AC DC power supply Medical&l.T.E.safety approvals 2 MOPP input to output isolation Leakage currents ≤100uA
90W
80-264VAC
Meets medical & I.T.E. safety
Leakage current ≤100μA
DOE level VI
≤ 0.21W standby power
11V to 54V outputs, up to 140W
Up to 5,000m operating altitude
4 types of AC inlet
Application place: oxygen concentrator, electric treatment chair, infant incubator, electrochemical analyzer, laser therapy device, medical air compressor


Safety Standards – IEC60601,EN60601,UL60601
Safety Approvals – CE, CB ,TUV-Mark ,UL
| Model Number | Power(W) | Input Voltage Range(VDC) | Output Voltage(VDC) | Output Current(A) | Operating Temperature Range(℃) | Safety Standards |
|---|---|---|---|---|---|---|
| UES90C-SPAZ | 77.0 | 80-264 | 11.0 | 0.01-7.00 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 84.0 | 80-264 | 12.0 | 0.01-7.00 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 15.0 | 0.01-6.00 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 17.0 | 0.01-5.29 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 19.0 | 0.01-4.74 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 22.0 | 0.01-4.09 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 24.0 | 0.01-3.75 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 26.0 | 0.01-3.46 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 30.0 | 0.01-3.00 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 33.0 | 0.01-2.73 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 36.0 | 0.01-2.50 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 39.0 | 0.01-2.31 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 43.0 | 0.01-2.09 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 46.0 | 0.01-1.95 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 48.0 | 0.01-1.88 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 52.0 | 0.01-1.73 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 54.0 | 0.01-1.67 | 0 ~ +40 | CB, CCC, CE, NRTL |






It supports a wide output range from 11V to 54V.
The adapter delivers up to 90 watts of continuous power.
It's ideal for ultrasound systems, CPAP/BiPAP machines, centrifuges, infusion devices, and medical imaging units.
Yes, it can be built to meet IEC 60601-1 and other medical safety standards.
Yes, it supports up to 54V for devices like laser therapy systems and medical carts.
Absolutely. It includes protections for over-voltage, over-current, short-circuit, and overheating.
Yes, it features a fanless design for silent and reliable operation.
Yes, its compact and external design makes it ideal for portable equipment.
Yes, it accepts 100–240V AC input, suitable for global use.
Yes, we provide multiple DC connectors and cable customizations.

Home Medical Power Supply UES100B-SPCZ/UES100C-SPCZ Desktop homecare 15v 20v switching AC DC power supply Medical&l.T.E.safety approvals 2 MOPP input to output isolation Leakage currents ≤100uA

Home Medical Power Supply UES100LCP2-SPC 12 volt regulated power supply, wall plug external switching power supply Meets communication and medical safety certification 2 MOPP isolation

Home Desktop Medical External Power Supply UES100DZ-SPA Series 100W 12V AC to DC Desktop Medical External Power Supply 2Mopp USB Type 100 W 80 ~

Introduction: EMC Is a Safety Requirement, Not a Performance Feature In medical electrical equipment, electromagnetic compatibility (EMC) is not merely about avoiding interference—it is a

1xMOPP vs 2xMOPP in Medical Power Supplies Isolation requirements in medical power supplies are a cornerstone of IEC 60601-1 compliance. Understanding the distinction between 1xMOPP (Means

Introduction: Certification Failures Rarely Start at the Test Lab Most medical device certification failures are not caused by last-minute mistakes.They originate months earlier—often at the

Introduction: Patient Connection Changes Everything In medical device design, patient connection is a regulatory boundary, not a functional feature.Once a device is classified as patient-connected,

Introduction: Power Supply Selection Is a Certification Decision medical power supply selection is often treated as a late-stage electrical task. In reality, it is one of

When you are selling medical devices globally, the medical power adapter is never just a “charger.” It is the final and most critical safety barrier
For additional assistance, please complete the form below, and an associate will be in touch with you shortly.

Quankang Power – Leading Power Supply Manufacturer
Let us know more about your project!
Hi! Thanks for reaching out to Quankang!
Please provide the following details so we can offer the best switching power supply solution:
1. Your full name and email address
2. Specifications or use case for the power supply (e.g., wattage, voltage, application)
3. Order quantity or budget
Our team will get back to you soon!
WhatsApp Us
🟢 Online | Privacy policy
WhatsApp us